Sign in →

Test Code T3TOTAL T3 (Triiodothyronine), Total, Serum

Additional Codes

Mayo Test ID
T3

Reporting Name

T3 (Triiodothyronine), Total, S

Useful For

Second-order testing for hyperthyroidism in patients with low thyroid-stimulating hormone values and normal thyroxine levels

 

Diagnosing triiodothyronine (T3) toxicosis

 

This test is not useful for general screening of the population without clinical suspicion of hyperthyroidism.

Testing Algorithm

For information see Thyroid Function Ordering Algorithm.

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions: Centrifuge and aliquot serum into plastic vial.


Specimen Minimum Volume

0.75 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 7 days
  Frozen  30 days

Reference Values

Pediatric

0-5 days: 73-288 ng/dL

6 days-2 months: 80-275 ng/dL

3-11 months: 86-265 ng/dL

1-5 years: 92-248 ng/dL

6-10 years: 93-231 ng/dL

11-19 years: 91-218 ng/dL

 

Adult (≥20 years): 80-200 ng/dL

 

For SI unit Reference Values, see www.mayocliniclabs.com/order-tests/si-unit-conversion.html

Day(s) Performed

Monday through Saturday

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

84480

LOINC Code Information

Test ID Test Order Name Order LOINC Value
T3 T3 (Triiodothyronine), Total, S 83124-8

 

Result ID Test Result Name Result LOINC Value
T3 T3 (Triiodothyronine), Total, S 83124-8

Clinical Information

Thyroid hormones regulate numerous developmental, metabolic, and neural activities throughout the body. The thyroid gland synthesizes 2 hormones. The 2 main hormones secreted by the thyroid gland are thyroxine (T4), which contains 4 atoms of iodine, and triiodothyronine (T3). T3 production in the thyroid gland constitutes approximately 20% of the total T3; the rest is generated by the conversion (deiodination) of T4 to T3. T3 is also produced by conversion (deiodination) of T4 in peripheral tissues. Circulating levels of T4 are much greater than T3 levels, but T3 is biologically the most metabolically active hormone (3-4 times more potent than T4), although its effect is briefer due to its shorter half-life compared to T4.

 

Thyroid hormones circulate primarily bound to carrier proteins (eg, thyroid-binding globulin [TBG], prealbumin, and albumin), whereas only a small fraction circulates unbound (free). Only the free forms are metabolically active. While both T3 and T4 are bound to TBG, T3 is bound less firmly than T4. Total T3 consists of both the bound and unbound fractions.

 

In hyperthyroidism, both T4 and T3 levels are usually elevated, but in a small subset of hyperthyroid patients, only T3 is elevated (T3 toxicosis).

 

In hypothyroidism, T4 and T3 levels are decreased. T3 levels are frequently low in sick or hospitalized euthyroid patients.

Interpretation

Triiodothyronine (T3) values above 200 ng/dL in adults or over age-related cutoffs in children are consistent with hyperthyroidism or increased thyroid hormone-binding proteins.

 

Abnormal levels (high or low) of thyroid hormone-binding proteins (primarily albumin and thyroid-binding globulin) may cause abnormal T3 concentrations in euthyroid patients.

Cautions

Triiodothyronine (T3) is not a reliable marker for hypothyroidism.

 

Therapy with amiodarone can lead to depressed T3 values.

 

Phenytoin, phenylbutazone, and salicylates cause a release of T3 from the binding proteins, thus leading to a reduction in the total T3 hormone level at normal free T3 levels.

 

Autoantibodies to thyroid hormones can interfere with the assay.

 

Binding protein anomalies may cause values that deviate from the expected results. Pathological concentrations of binding proteins can lead to results outside the reference range, although the patient may be in a euthyroid state. Free T3 or free T4 testing is indicated in these cases.

 

In rare cases, some individuals can develop antibodies to mouse or other animal antibodies (often referred to as human anti-mouse antibodies [HAMA] or heterophile antibodies), which may cause interference in some immunoassays. The presence of antibodies to streptavidin or ruthenium also rarely occur and may interfere with this assay. Caution should be used in interpretation of results, and the laboratory should be alerted if the result does not correlate with the clinical presentation.

 

T3 has a 15-fold higher affinity for thyroid receptor compared to T4.

 

Serum biotin concentrations up to 1200 ng/mL do not interfere with this assay. Concentrations up to 1200 ng/mL may be present in specimens collected from patients taking extremely high doses of biotin up to 300 mg per day.(1) In a study among 54 healthy volunteers, supplementation with 20 mg/day biotin resulted in a maximum serum biotin concentration of 355 ng/mL 1-hour post-dose.(2)

Report Available

1 to 3 days

Reject Due To

Gross hemolysis Reject
Gross lipemia OK
Gross icterus OK

Method Name

Electrochemiluminescence Immunoassay