Test Code SGSS Synthetic Glucocorticoid Screen, Serum
Reporting Name
Synthetic Glucocorticoid Screen, SUseful For
Confirming the presence of listed synthetic glucocorticoids (see Interpretation)
Confirming the cause of secondary adrenal insufficiency
This test is not useful for detection of fluticasone propionate.
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
SerumOrdering Guidance
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 2 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
1.1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Frozen (preferred) | 14 days | |
Refrigerated | 7 days | ||
Ambient | 24 hours |
Reference Values
Negative
Cutoff concentrations
Betamethasone: 0.10 mcg/dL
Budesonide: 0.20 mcg/dL
Dexamethasone: 0.10 mcg/dL
Fludrocortisone: 0.10 mcg/dL
Megestrol acetate: 0.10 mcg/dL
Methylprednisolone: 0.10 mcg/dL
Prednisolone: 0.10 mcg/dL
Prednisone: 0.10 mcg/dL
Triamcinolone acetonide: 0.10 mcg/dL
Values for normal patients not taking these synthetic glucocorticoids should be less than the cutoff concentration (detection limit).
Day(s) Performed
Wednesday
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
80299
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
SGSS | Synthetic Glucocorticoid Screen, S | 43141-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
23593 | Betamethasone | 41745-1 |
23594 | Budesonide | 41747-7 |
23595 | Dexamethasone | 14062-4 |
23596 | Fludrocortisone | 41754-3 |
23600 | Megestrol Acetate | 41762-6 |
23601 | Methylprednisolone | 14186-1 |
23602 | Prednisolone | 12727-4 |
23603 | Prednisone | 12434-7 |
23605 | Triamcinolone Acetonide | 41767-5 |
Clinical Information
Synthetic glucocorticoids are widely used and have important clinical utility both as anti-inflammatory and immunosuppressive agents. The medical use of these agents, as well as their surreptitious use, can sometimes lead to a confusing clinical presentation. Patients exposed to these steroids may present with clinical features of Cushing syndrome but with suppressed cortisol levels and evidence of hypothalamus-pituitary-adrenal axis suppression.
Interpretation
This test screens for and quantitates, if present, the following synthetic glucocorticoids: betamethasone, budesonide, dexamethasone, fludrocortisone, megestrol acetate, methylprednisolone, prednisolone, prednisone, and triamcinolone acetonide.
The presence of synthetic glucocorticoids in serum indicates current or recent use of these compounds. Since several of these compounds exceed the potency of endogenous cortisol by 1 or more orders of magnitude, even trace levels may be associated with cushingoid features.
Cautions
This method cannot detect all available synthetic steroids available either as pharmaceutical compounds or chemicals present in food. The assay confirms only the listed synthetic glucocorticoids. For more information see Interpretation.
Lack of detection does not preclude use of synthetic glucocorticoids because adrenal suppression may persist for some time after the exogenous steroid is discontinued.
Report Available
5 to 10 daysReject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Method Name