Test Code PCALC.1 PROCALCITONIN
Methodology
VITROS Brahms - Chemiluminescence
Specimen Requirements
Submit only 1 of the following specimens:
Preferred:
Serum
Serum Gel Tube
Container/Tube: Serum gel tube(s)
Specimen Volume: 1 mL (minimum volume: 0.5 mL) of
serum-Grossly hemolyzed specimen is not acceptable.
Collection Instructions: Spin down within 1 hour of draw.
Note: Label specimen appropriately (serum).
Alternate:
Serum
Plain, Red-Top Tube
Container/Tube: Plain, red-top tube(s)
Specimen Volume: 1 mL (minimum volume: 0.5 mL) of
serum-Grossly hemolyzed specimen is not acceptable.
Collection Instructions: Spin down within 1 hour of draw.
Note: Label specimen appropriately (serum).
Alternate:
Plasma
Green-Top
Container/Tube: Lithium heparin, green-top tube(s)
Specimen Volume: 1 mL (minimum volume: 0.5 mL) of
serum-Grossly hemolyzed specimen is not acceptable.
Collection Instructions: Spin down within 1 hour of draw.
Note: Label specimen appropriately (plasma).
EDTA
Container/Tube: Lavender-top tube(s)
Specimen Volume: 1 mL (minimum volume: 0.5 mL) of
serum-Grossly hemolyzed specimen is not acceptable.
Collection Instructions: Spin down within 1 hour of draw.
Note: Label specimen appropriately (plasma).
NOTE: Gross hemolysis, gross lipemia, and marked icterus are unacceptable.
Day(s) Test Set Up
Monday through Sunday
Reference Values
Children >48 hours - Adults: < 0.1 ng/mL
Performing Laboratory
Logan Health Medical Center Laboratory
Test Classification and CPT Coding
84145
Specimen Transport Temperature
Refrigerate