Test Code MHPRP Metamycoplasma hominis, Molecular Detection, PCR, Plasma

Useful For

Rapid, sensitive, and specific identification of Metamycoplasma hominis from plasma

 

This test is not intended for medicolegal use.

Method Name

Real-Time Polymerase Chain Reaction (PCR) using LightCycler and Fluorescent Resonance Energy Transfer (FRET)

Reporting Name

Mycoplasma hominis PCR, P

Specimen Type

Plasma EDTA


Ordering Guidance


 



Shipping Instructions


Ship specimen refrigerated.



Specimen Required


The high sensitivity of amplification by polymerase chain reaction requires the specimen to be processed in an environment in which contamination of the specimen by Metamycoplasma hominis DNA is unlikely.

 

Collection Container/Tube:

Preferred: Lavender top (EDTA)

Acceptable: Royal blue top (EDTA), pink top (EDTA)

Submission Container/Tube: Screw-capped, sterile container

Specimen Volume: 1 mL

Collection Instructions: Centrifuge and aliquot plasma into a sterile vial within 24 hours of collection.


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Plasma EDTA Refrigerated (preferred) 7 days
  Frozen  7 days

Reject Due To

  All specimens will be evaluated at Mayo Clinic Laboratories for test suitability

Clinical Information

Metamycoplasma hominis, previously Mycoplasma hominis, has been associated with a number of clinically significant infections, although it is also part of the normal urogenital microbiota.

 

M hominis may be found in the respiratory specimens and spinal fluid of neonates. Although the clinical significance of such findings is often unclear, as spontaneous clinical recovery may occur without specific treatment. In premature infants, clinical manifestations of meningoencephalitis have been reported.

 

M hominis may play a role in some cases of pelvic inflammatory disease, usually in combination with other organisms. M hominis may be isolated from amniotic fluid of women with preterm labor, premature rupture of membranes, spontaneous term labor, or chorioamnionitis; there is evidence that it may be involved in postpartum fever or fever following abortion, usually as a complication of endometritis.

 

M hominis has rarely been associated with septic arthritis (including prosthetic joint infection), pyelonephritis, intraabdominal infection, wound infection, endocarditis, central nervous system infection (including meningoencephalitis, brain abscess, central nervous system shunt infection and subdural empyema), pneumonia, and infected pleural and pericardial effusions. Extragenital infection typically occurs in those with hypogammaglobulinemia or depressed cell-mediated immunity. In lung transplant recipients in particular, M hominis has been associated with pleuritis and mediastinitis. Recent evidence implicates donor transmission in some cases of M hominis infection in lung transplant recipients.

 

Polymerase chain reaction (PCR) detection of M hominis is sensitive, specific, and provides same-day results. Although this organism can occasionally be detected in routine plate cultures, this is neither a rapid nor a sensitive approach to detection. Specialized cultures are more time consuming than the described PCR assay. The described PCR assay has replaced conventional culture for M hominis at Mayo Clinic Laboratories due to its speed and equivalent performance to culture.

Reference Values

Not applicable

Interpretation

A positive polymerase chain reaction (PCR) result for the presence of a specific sequence found within the Metamycoplasma hominis tuf gene indicates the presence of M hominis DNA in the specimen.

 

A negative PCR result indicates the absence of detectable M hominis DNA in the specimen, but it does not rule-out infection as false-negative results may occur due to inhibition of PCR, sequence variability underlying the primers and probes, or the presence of M hominis in quantities less than the limit of detection of the assay.

Cautions

Interfering substances may affect the accuracy of this assay; results should always be interpreted in conjunction with clinical and epidemiological findings

 

Since Metaycoplasma hominis may be part of the normal microbiota, results should be interpreted accordingly.

 

This test does not detect other species of Metamycoplasma or Ureaplasma (including Mycoplasma pneumoniae, a common cause of community acquired pneumonia)

Day(s) Performed

Monday through Friday

Report Available

3 to 4 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

87798

LOINC Code Information

Test ID Test Order Name Order LOINC Value
MHPRP Mycoplasma hominis PCR, P 68546-1

 

Result ID Test Result Name Result LOINC Value
MPSRC Specimen Source 31208-2
44134 Mycoplasma hominis PCR, P 68546-1