Test Code IDH2 IHD2, R172K Mutation, Immunostain, Technical Component Only


Ordering Guidance


This test includes only technical performance of the stain (no pathologist interpretation is performed). If diagnostic consultation by a pathologist is required, order PATHC / Pathology Consultation.



Shipping Instructions


Attach the green "Attention Pathology" address label (T498) and the pink Immunostain Technical Only label included in the kit to the outside of the transport container



Specimen Required


Specimen Type: Tissue

Supplies: Immunostain Technical Only Envelope (T693)

Container/Tube: Immunostain Technical Only Envelope

Preferred:

-Formalin-fixed, paraffin-embedded tissue block

OR

-2 Unstained, positively charged glass slides (25- x 75- x 1-mm) per test ordered; sections 4-microns thick

Acceptable: None


Useful For

Identification of IDH2 R172K mutant protein in angioimmunoblastic T-cell lymphoma or acute myeloid leukemia

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
IHTOA IHC Additional, Tech Only No No
IHTOI IHC Initial, Tech Only No No

Testing Algorithm

For the initial technical component only immunohistochemical (IHC) stain performed, the appropriate bill-only test ID will be reflexed and charged (IHTOI). For each additional technical component only IHC stain performed, an additional bill-only test ID will be reflexed and charged (IHTOA).

Method Name

Immunohistochemistry (IHC)

Reporting Name

IDH2, R172K Mutation, IHC Tech Only

Specimen Type

TECHONLY

Specimen Stability Information

Specimen Type Temperature Time Special Container
TECHONLY Ambient (preferred)
  Refrigerated 

Reject Due To

Wet/frozen tissue 
Cytology smears 
Nonformalin fixed tissue 
Nonparaffin embedded tissue 
Noncharged slides 
ProbeOn slides 
Snowcoat slides 
Reject 

Clinical Information

The IDH2 R172K mutation is present in a subset of cases of angioimmunoblastic T-cell lymphoma (AITL). Detection of the mutant protein using a mutation-specific antibody is useful in the diagnosis of AITL. This mutation may also be found in cases of acute myeloid leukemia.

Interpretation

This test does not include pathologist interpretation, only technical performance of the stain. If interpretation is required, order PATHC / Pathology Consultation for a full diagnostic evaluation or second opinion of the case.

 

The positive and negative controls are verified as showing appropriate immunoreactivity. If a control tissue is not included on the slide, a scanned image of the relevant quality control tissue is available upon request; call 855-516-8404.

 

Interpretation of this test should be performed in the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.

Cautions

Age of a cut paraffin section can affect immunoreactivity. Stability thresholds vary widely among published literature and are antigen dependent. Best practice is for paraffin sections to be cut within 6 weeks.

 

The charge of glass slides can be affected by environmental factors and subsequently may alter slide staining. Sending unsuitable glass slides can result in inconsistent staining due to poor slide surface chemistry.

 

Best practices for storage of positively charged slides:

-Minimize time slides are stored after being unpackaged

-Limit exposure to high humidity and heat

-Minimize exposure to plastics

Day(s) Performed

Monday through Friday

Report Available

1 to 3 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

88342-TC, primary

88341-TC, if additional IHC

LOINC Code Information

Result ID Test Result Name Result LOINC Value
616904 IDH2, R172K Mutation, IHC Tech Only No LOINC Needed