Test Code HCGQ1 BETA HCG, QUANTITATIVE, SERUM
Methodology
Chemiluminescent Immunoassay - OrthoClinical Diagnostics Vitros 7600 XT
Useful for confirmation of pregnancy; diagnosis of ectopic pregnancy, threatened abortion, multiple gestations, and some germ cell tumors.
Specimen Requirements
Submit only 1 of the following specimens:
Preferred:
Serum
Serum Gel Tube
Container/Tube: Serum gel tube(s)
Specimen Volume: 2 mL (minimum volume: 1 mL) of serum
Collection Instructions: Spin down within 4 hours of draw.
Note: Label specimen appropriately (serum).
Alternate:
Serum
Plain, Red-Top Tube
Container/Tube: Plain, red-top tube(s)
Specimen Volume: 2 mL (minimum volume: 1 mL) of serum
Collection Instructions: Spin down within 4 hours of draw.
Note: Label specimen appropriately (serum).
Alternate:
Plasma
Container/Tube: Green-top (lithium heparin) tube(s) or lavender-top (EDTA) tube(s)
Specimen Volume: 2 mL (minimum volume: 1 mL) of plasma
Collection Instructions: Spin down within 4 hours of draw.
Note: Label specimen appropriately (plasma).
Specimen Retention Time
6 days
Day(s) Test Set Up
Monday through Friday, Routine
Available STAT Monday through Sunday
Reference Values
Males: <3 mIU/mL
Females, nonpregnant: <5 mIU/mL
Females, post-menopausal: <7 mIU/mL
Females, pregnant (gestational age):
0-1 week: 0-50 mIU/mL
1-2 weeks: 40-300 mIU/mL
2-3 weeks: 100-1000 mIU/mL
3-4 weeks: 500-6000 mIU/mL
4-6 weeks: 3600-135000 mIU/mL
6-10 weeks: 22600-151000 mIU/mL
Tumor markers are not specific for malignancy, and values may vary by method.
Performing Laboratory
Logan Health Medical Center-Chemistry
Test Classification and CPT Coding
84702
Specimen Transport Temperature
Refrigerate