Sign in →

Test Code GNANT Antithrombin Deficiency, SERPINC1 Gene, Next-Generation Sequencing, Varies


Ordering Guidance


This test should only be considered if clinical and family history, initial coagulation screens, and/or initial antithrombin (AT) activity and antigen testing results suggest a diagnosis of antithrombin deficiency (see Testing Algorithm).

 

This test does not measure AT activity levels. For assessment of AT activity, order ATTF / Antithrombin Activity, Plasma.

 

If genetic testing for hereditary blood clotting disorders using a larger panel is desired, a 16-gene comprehensive thrombosis panel is available; order GNTHR / Thrombosis Disorders, Comprehensive Gene Panel, Next-Generation Sequencing, Varies.

 

Testing for the SERPINC1 gene as part of a customized panel is available. For more information see CGPH / Custom Gene Panel, Hereditary, Next-Generation Sequencing, Varies.

 

Targeted testing for familial variants (also called site-specific or known variants testing) is available for the SERPINC1 gene. See FMTT / Familial Variant, Targeted Testing, Varies. To obtain more information about this testing option, call 800-533-1710.



Shipping Instructions


Specimen preferred to arrive within 96 hours of collection.



Necessary Information


Rare Coagulation Disorder Patient Information is required. Testing may proceed without the patient information; however, the information aids in providing a more thorough interpretation. Ordering providers are strongly encouraged to fill out the form and send with the specimen.



Specimen Required


Specimen Type: Whole blood

Patient Preparation: A previous bone marrow transplant from an allogenic donor will interfere with testing. Call 800-533-1710 for instructions for testing patients who have received a bone marrow transplant.

Container/Tube:

Preferred: Lavender top (EDTA)

Acceptable: Yellow top (ACD)

Specimen Volume: 3 mL

Collection Instructions:

1. Invert several times to mix blood.

2. Send whole blood specimen in original tube. Do not aliquot.

Specimen Stability Information: Ambient (preferred) 4 days/Refrigerated


Forms

1. Rare Coagulation Disorder Patient Information (T824) is required.

2. New York Clients-Informed consent is required. Document on the request form or electronic order that a copy is on file. The following documents are available:

-Informed Consent for Genetic Testing (T576)

-Informed Consent for Genetic Testing (Spanish) (T826)

3. If not ordering electronically, complete, print, and send an Coagulation Test Request (T753) with the specimen.

Useful For

Evaluating antithrombin AT deficiency in patients with a personal or family history suggestive of this hereditary thrombophilia

 

Confirming an AT deficiency diagnosis with the identification of a known or suspected disease-causing alteration in the SERPINC1 gene, particularly in patients with borderline low AT activity levels

 

Determining the disease-causing alteration within the SERPINC1 gene to delineate the underlying molecular defect in a patient with a laboratory diagnosis of AT deficiency

 

Prognosis and risk assessment based on the genotype-phenotype correlations

 

Ascertaining the variant status of family members related to an individual with a confirmed SERPINC1 variant for the purposes of informing clinical management and genetic counseling

 

Evaluating individuals with apparent heparin resistance

 

This test is not intended for prenatal diagnosis.

Testing Algorithm

The clinical workup for antithrombin (AT) deficiency should begin with an AT activity assay.

 

Genetic testing for AT deficiency is indicated if:

-AT activity assay is less than 80% of normal (Note: reference range may vary depending on the locally established reference range)

-There is a clinical suspicion of hereditary thrombophilia and possible AT deficiency due to family history or atypical clinical presentation

-Acquired (nongenetic) causes of AT deficiency have been excluded (eg, liver disease, acute thrombosis, heparin therapy, nephrotic syndrome, disseminated intravascular coagulation, and chemotherapeutic agents such an L-asparaginase)

Note: Low AT levels may be temporarily associated with other conditions such severe trauma, severe burns, or the presence of acute blood clots.

Method Name

Sequence Capture and Targeted Next-Generation Sequencing (NGS) followed by Polymerase Chain Reaction (PCR) and Sanger Sequencing

Reporting Name

SERPINC1 Gene, Full Gene NGS

Specimen Type

Varies

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Varies

Reject Due To

All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Clinical Information

Antithrombin (AT) deficiency is a rare hereditary blood clotting disorder (thrombophilia) associated with germline variants in the SERPINC1 gene. It is inherited in an autosomal dominant manner with variable penetrance; both men and women may be affected. The prevalence varies widely, with estimates between 1 in 500 to 1 in 5000 individuals.(1-3)

 

AT deficiency is characterized by defects in the concentration or function of AT, a natural anticoagulant in blood plasma. It leads to the highest risk of venous thromboembolism among the known inherited thrombophilias. In some cases, patients have resistance to heparin therapy. Affected women have a particularly elevated risk for pregnancy-related complications, including thromboembolic events during pregnancy and after delivery, as well as fetal loss.(4-7)

 

Acquired (nongenetic) AT deficiency is more common than inherited AT deficiency and should be excluded prior to genetic testing. Causes of acquired AT deficiency include liver disease, acute thrombosis, heparin therapy, nephrotic syndrome, disseminated intravascular coagulation, and chemotherapeutic agents, such an L-asparaginase.(4,8)

 

The British Society for Haematology provides guidelines regarding diagnosis, management, and laboratory testing for individuals with hereditary thrombophilias including AT deficiency.(9)

Reference Values

An interpretive report will be provided.

Interpretation

All detected variants are evaluated according to American College of Medical Genetics and Genomics recommendations.(10) Variants are classified based on known, predicted, or possible pathogenicity and reported with interpretive comments detailing their potential or known significance.

Cautions

Clinical Correlations:

Test results should be interpreted in the context of clinical findings, family history, and other laboratory data. Misinterpretation of results may occur if the information provided is inaccurate or incomplete.

 

If testing was performed because of a clinically significant family history, it is often useful to first test an affected family member. Detection of a reportable variant in an affected family member would allow for more informative testing of at-risk individuals.

 

To discuss the availability of additional testing options or for assistance in the interpretation of these results, contact the Mayo Clinic Laboratories genetic counselors at 800-533-1710.

 

Technical Limitations:

Next-generation sequencing may not detect all types of genomic variants. In rare cases, false-negative or false-positive results may occur. The depth of coverage may be variable for some target regions; assay performance below the minimum acceptable criteria or for failed regions will be noted. Given these limitations, negative results do not rule out the diagnosis of a genetic disorder. If a specific clinical disorder is suspected, evaluation by alternative methods can be considered.

 

There may be regions of genes that cannot be effectively evaluated by sequencing or deletion and duplication analysis as a result of technical limitations of the assay, including regions of homology, high guanine-cytosine (GC) content, and repetitive sequences. Confirmation of select reportable variants will be performed by alternate methodologies based on internal laboratory criteria.

 

This test is validated to detect 95% of deletions up to 75 base pairs (bp) and insertions up to 47 bp. Deletions-insertions (delins) of 40 or more bp, including mobile element insertions, may be less reliably detected than smaller delins.

 

Deletion/Duplication Analysis:

This analysis targets single and multi-exon deletions/duplications; however, in some instances, single exon resolution cannot be achieved due to isolated reduction in sequence coverage or inherent genomic complexity. Balanced structural rearrangements (such as translocations and inversions) may not be detected.

 

This test is not designed to detect low levels of mosaicism or to differentiate between somatic and germline variants. If there is a possibility that any detected variant is somatic, additional testing may be necessary to clarify the significance of results.

 

For detailed information regarding gene-specific performance and technical limitations, see Method Description or contact a laboratory genetic counselor.

 

If the patient has had an allogeneic hematopoietic stem cell transplant or a recent blood transfusion, results may be inaccurate due to the presence of donor DNA. Call Mayo Clinic Laboratories for instructions for testing patients who have received a bone marrow transplant.

 

Reclassification of Variants:

Currently, it is not standard practice for the laboratory to systematically review previously classified variants on a regular basis. The laboratory encourages healthcare providers to contact the laboratory at any time to learn how the classification of a particular variant may have changed over time. Due to broadening genetic knowledge, it is possible that the laboratory may discover new information of relevance to the patient. Should that occur, the laboratory may issue an amended report.

 

Variant Evaluation:

Evaluation and categorization of variants are performed using published American College of Medical Genetics and Genomics and the Association for Molecular Pathology recommendations as a guideline.(10) Other gene-specific guidelines may also be considered. Variants are classified based on known, predicted, or possible pathogenicity and reported with interpretive comments detailing their potential or known significance. Variants classified as benign or likely benign are not reported.

 

Multiple in silico evaluation tools may be used to assist in the interpretation of these results. The accuracy of predictions made by in silico evaluation tools is highly dependent upon the data available for a given gene, and periodic updates to these tools may cause predictions to change over time. Results from in silico evaluation tools should be interpreted with caution and professional clinical judgment.

 

Rarely, incidental or secondary findings may implicate another predisposition or presence of active disease. These findings will be carefully reviewed to determine whether they will be reported.

Day(s) Performed

Varies

Report Available

28 to 42 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

81479

LOINC Code Information

Test ID Test Order Name Order LOINC Value
GNANT SERPINC1 Gene, Full Gene NGS 93814-2

 

Result ID Test Result Name Result LOINC Value
619006 Test Description 62364-5
619007 Specimen 31208-2
619008 Source 31208-2
619009 Result Summary 50397-9
619010 Result 82939-0
619011 Interpretation 59465-5
619012 Additional Results 82939-0
619013 Resources 99622-3
619014 Additional Information 48767-8
619015 Method 85069-3
619016 Genes Analyzed 82939-0
619017 Disclaimer 62364-5
619018 Released By 18771-6