Sign in →

Test Code CULTBCF FUNGAL CULTURE, BLOOD

Methodology

Agar Slants

Specimen Requirements

Draw blood cultures before starting antifungal therapy. 

 

Blood

Container/Tube: Yellow-top (SPS) tube(s)

Specimen Volume: 2 mL of blood

Collection Instructions: Draw blood as follows:

1. Disinfect stopper of SPS tube(s) with 70% alcohol and allow to dry. Repeat with iodine.

2. Use ChloraPrep® kit as follows to disinfect skin:

  • Peel off package cover to remove ChloraPrep®. 
  • Hold applicator without touching sponge. Pinch wings once to break ampule. You should hear a pop.
  • Saturate sponge with ChloraPrep® by gently pressing it against venipuncture area. Using a back and forth motion, completely wet treatment area for 30 seconds.
  • Allow to dry completely (30 to 60 seconds). Do not blot or wipe the solution away.  Discard applicator after a single use.

3. If ChloraPrep® kits are not available, disinfect skin as follows:

  • Thoroughly cleanse venipuncture site with 70% alcohol moving in concentric circles to periphery. Allow to dry. If site must be touched during venipuncture, disinfect gloved fingers.
  • Repeat Step #3A using iodine. Allow to dry 30 to 60 seconds or wipe with a sterile gauze.

4. Draw blood into tube(s).

5. Gently invert tube(s) 4 to 5 times to mix.

6. Label tube(s) with patient’s legal name, date and actual time of collection, and type of specimen.

Note:

1. Blood cultures should not be drawn through a line unless they cannot be obtained by venipuncture. If drawn from a line, consult microbiology about volume to be discarded.

2. Method of specimen collection and amount of blood drawn directly influence success of recovery of isolates and interpretation of results.

3. Factors directly influencing culture results:

  • Volume of blood drawn is perhaps the most important factor.
  • Method of skin disinfection is also critical.

4. Specimen source is required.

 

Bone Marrow

Container/Tube: Yellow-top (SPS) tube(s)

Specimen Volume: 0.5 mL (minimum volume: 0.1 mL) of bone marrow

Collection Instructions: Collect specimen as follows; sterile technique must be maintained in all steps of collection.


1. Disinfect stopper of tube(s) with 70% alcohol and allow to dry. Repeat with iodine.
2. Thoroughly cleanse overlaying skin with 70% alcohol, followed by 2% iodine tincture, moving in concentric circles to periphery. Do not remove iodine.
3. Specimen must be collected by physician trained in this procedure.

  • Obtain bone marrow.
  • Place sterile, 18-gauge needle on syringe and inject bone marrow into tube(s) by puncturing stopper with needle.

4. Gently invert tube(s) 4 to 5 times to mix.

5. Label tube(s) with patient’s legal name, date and actual time of collection, and type of specimen.

6. Protect specimen from temperature extremes. When shipping, try to keep specimen as close to ambient temperature as possible.

Note: Specimen source is required.

Day(s) Test Set Up

Monday through Sunday

Reference Values

No growth
Critical value (automatic call-back): all positives

Performing Laboratory

Logan Health Medical Center Laboratory

Test Classification and CPT Coding

87103

Specimen Transport Temperature

Ambient/Refrigerate NO/Frozen NO