Sign in →

Test Code CMAT Chromosomal Microarray, Tumor, Fresh or Frozen

Useful For

Genomic characterization of tumor for copy number imbalances and loss of heterozygosity

 

Assisting in the diagnosis and classification of malignant neoplasms, including hematolymphoid malignancies

 

Evaluating the prognosis for patients with malignant tumors

Testing Algorithm

DNA is extracted from the specimen prior to hybridization to the microarray.

Method Name

Chromosomal Microarray (CMA)

Reporting Name

Chromosomal Microarray, Tumor

Specimen Type

Varies


Ordering Guidance


This test is not performed on formalin-fixed, paraffin-embedded (FFPE) specimens. If testing is needed for FFPE specimens, order CMAPT / Chromosomal Microarray, Tumor, Formalin-Fixed Paraffin-Embedded.

 

If an FFPE specimen is submitted, this test will be canceled and CMAPT / Chromosomal Microarray, Tumor, Formalin-Fixed Paraffin-Embedded will be added and performed as the appropriate test.



Additional Testing Requirements


 



Shipping Instructions


Advise Express Mail or equivalent if not on courier service.



Necessary Information


1. A reason for testing must be provided for testing to be performed.

2. A pathology report should accompany the specimen. If this information is not available at the time of order, submit as soon as possible for appropriateness of testing and to aid in interpretation of results.



Specimen Required


Submit only 1 of the following specimens:

Supplies: Hank's Solution (T132)

 

Specimen Type: Tumor biopsy

Container/Tube: Sterile container with sterile Hank's balanced salt solution, Ringer's solution, or normal saline

Specimen Volume: 0.5-3 cm(3) or larger

 

Specimen Type: Lymph node

Container/Tube: Sterile container with sterile Hank's balanced salt solution, Ringer's solution, or normal saline.

Specimen Volume: 1 cm(3)

 

Specimen Type: Skin biopsy

Container/Tube: Sterile container with sterile Hank's balanced salt solution, Ringer's solution, or normal saline.

Specimen Volume: 4-mm diameter

Collection Instructions:

1. Wash biopsy site with an antiseptic soap.

2. Thoroughly rinse area with sterile water.

3. Do not use alcohol or iodine preparations.

4. A local anesthetic may be used.

5. Biopsy specimens are best taken by punch biopsy to include full thickness of dermis.


Specimen Minimum Volume

Tumor biopsy: 3 cm(3); Lymph node: 1 cm(3); Skin biopsy: 4 mm diameter

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Ambient (preferred)
  Refrigerated 

Reject Due To

All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Clinical Information

The importance of identifying chromosome abnormalities in malignant neoplasms is well established, and often provides important diagnostic, prognostic, and therapeutic information critical to proper patient management. Although many chromosomal abnormalities are large enough to be detected with conventional chromosome analysis, many others are below its limits of resolution, and conventional chromosome analysis does not detect copy-neutral loss of heterozygosity.

 

Chromosomal microarray (CMA) improves the diagnostic yield to identify genetic changes that are not detected by conventional chromosome analysis or fluorescence in situ hybridization (FISH) studies. CMA utilizes greater than 2 million copy number probes and approximately 750,000 single nucleotide polymorphism probes to detect copy number changes and regions of copy-neutral loss of heterozygosity.

 

Chromosomal microarray analysis is appropriate to identify gain or loss of chromosome material throughout the genome at a resolution of 30 to 60 kilobases.

CMA can:

-Define the size, breakpoints, and gene content of copy number changes to demonstrate the complexity of abnormalities

-Characterize unidentified chromosome material, marker chromosomes, and DNA amplification detected by conventional chromosome and FISH studies

-Determine if apparently balanced chromosome rearrangements identified by conventional chromosome studies have cryptic imbalances

-Assess regions of copy-neutral loss of heterozygosity, which is common in neoplasia and often masks homozygous mutations involving tumor suppressor genes

 

The limit of detection is dependent on size of the abnormality, type of abnormality (deletion or duplication) and DNA quality. When a deletion or duplication exceeds the reporting limits, mosaicism can confidently be detected as low as 25% and may be lower if the abnormality is large and DNA quality is good.

Reference Values

An interpretive report will be provided.

Interpretation

The interpretive report describes copy number changes and loss of heterozygosity that may be associated with the neoplastic process being evaluated. Abnormal clones with subclonal abnormalities will be discussed if identified.

 

The continual discovery and publication of novel copy number abnormalities and losses of heterozygosity associated with neoplastic processes means that the interpretation of any given detected abnormality may change with increased scientific understanding.

 

Although the presence of a clonal abnormality is usually associated with neoplasia, in some situations it may reflect a benign or constitutional genetic change. If a genetic change is identified that is likely constitutional and clearly pathogenic or likely pathogenic and/or related to the clinical reason for referral, this will be included in the report and follow-up with a medical genetic consultation may be suggested.

 

The absence of an abnormal clone may be the result of specimen collection from a site that is not involved in the neoplasm or may indicate that the disorder is caused by a point mutation that is not detectable by chromosomal microarray.

 

Chromosomal microarray, fluorescence in situ hybridization (FISH), and conventional cytogenetics are to some extent complementary methods. In some instances, additional FISH or conventional cytogenetic studies will be recommended to clarify interpretive uncertainties.

Cautions

This test is not approved by the US Food and Drug Administration, and it is best used as an adjunct to existing clinical and pathologic information.

 

This test does not detect balanced chromosome rearrangements such as reciprocal translocations, inversions, or balanced insertions.

 

This test does not detect point mutations/pathogenic variants, small insertions or deletions, trinucleotide repeat expansions, or other copy number abnormalities below the resolution of the assay, or other types of variants such as epigenetic changes.

 

This test may not detect mosaic abnormalities in small proportion of cells, and as such it is not recommended for minimal residual disease monitoring or for specimens with tumor contents less than 20% of sample.

 

The results of this test may reveal incidental and secondary findings unrelated to the original reason for referral.

Day(s) Performed

Monday through Sunday

Report Available

10 to 21 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

81277

LOINC Code Information

Test ID Test Order Name Order LOINC Value
CMAT Chromosomal Microarray, Tumor 94087-4

 

Result ID Test Result Name Result LOINC Value
54729 Result 62356-1
54730 Nomenclature 62356-1
54728 Result Summary 50397-9
54731 Interpretation 69965-2
CG905 Reason for Referral 42349-1
54743 Specimen 31208-2
54732 Source 31208-2
54733 Method 85069-3
53424 Additional Information 48767-8
54734 Released By 18771-6