Test Code CLFAT Cryptococcus Antigen Titer, Lateral Flow Assay, Spinal Fluid

Useful For

Monitoring Cryptococcus antigen titers in cerebrospinal fluid

 

Aiding in the diagnosis of cryptococcosis

 

This test should not be used as a test of cure or to guide treatment decisions.

Reporting Name

Cryptococcus Ag Titer, LFA, CSF

Specimen Type

CSF


Specimen Required


Container/Tube: Sterile vial

Specimen Volume: 0.5 mL


Specimen Minimum Volume

0.3 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
CSF Refrigerated (preferred) 14 days
  Frozen  14 days

Reject Due To

Gross hemolysis Reject

Clinical Information

Cryptococcosis is an invasive fungal infection caused by Cryptococcus neoformans or Cryptococcus gattii. C neoformans has been isolated from several sites in nature, particularly weathered pigeon droppings. C gattii was previously only associated with tropical and subtropical regions. More recently, however, this organism has been found to be endemic in British Columbia and the Pacific Northwestern United States and is associated with several different tree species.

 

Infection is usually acquired via the pulmonary route. Patients are often unaware of any exposure history. Approximately half of the patients with symptomatic disease have a predisposing immunosuppressive condition such as AIDS, steroid therapy, lymphoma, or sarcoidosis. Symptoms may include fever, headache, dizziness, ataxia, somnolence, and cough. While the majority of C neoformans infections occur in immunocompromised patient populations, C gattii is has a higher predilection for infection of healthy individuals.(1,2)

 

In addition to the lungs, cryptococcal infections frequently involve the central nervous system (CNS), particularly in patients infected with HIV. Mortality among patients with CNS cryptococcosis may approach 25% despite antibiotic therapy. Untreated CNS cryptococcosis is invariably fatal. Disseminated disease may affect any organ system and usually occurs in immunosuppressed individuals.

Reference Values

Negative

Reference values apply to all ages.

Interpretation

The presence of cryptococcal antigen in any body fluid (serum or cerebrospinal fluid [CSF]) is indicative of cryptococcosis.

 

Disseminated infection is usually accompanied by a positive serum test.

 

Declining titers may indicate regression of infection. However, monitoring titers to cryptococcal antigen should not be used as a test of cure or to guide treatment decisions. Low-level titers may persist for extended periods of time following appropriate therapy and resolution of infection.(3,4)

 

According to the College of American Pathologists (CAP, IMM.41840), CSF specimens submitted for initial diagnosis that test positive by the lateral flow assay, should also be submitted for routine fungal culture. Culture can aid in differentiating between the 2 common Cryptococcus species causing disease (Cryptococcus neoformans and Cryptococcus gattii) and can be used for antifungal susceptibility testing, if necessary. CSF specimens submitted to monitor antigen levels during treatment do not need to be cultured.

Cautions

A traumatic lumbar puncture and contamination of the cerebrospinal fluid (CSF) specimen with serum may lead to a positive Cryptococcus antigen result from CSF in patients without neuroinvasive cryptococcosis.

 

Cryptococcus antigen titers acquired by the lateral flow assay may be higher than titers achieved by other Cryptococcus antigen assays. Titers acquired by different assay methods are not interchangeable.

 

Cryptococcus antigen titers should be followed using the same assay.

 

A positive result is indicative of cryptococcosis; however, all test results should be reviewed in light of other clinical findings.

 

A negative result does not preclude diagnosis of cryptococcosis, particularly if only a single specimen has been tested and the patient shows symptoms consistent with cryptococcosis.

 

Testing should not be performed as a screening procedure for the general populations and should only be performed when clinical evidence suggests the diagnosis of cryptococcal disease.

 

Although rare, extremely high concentrations of cryptococcal antigen can result in weak test lines and in extreme instances, yield negative test results.

 

This assay has not been evaluated for cross-reactivity in patients with trichosporonosis.

Day(s) Performed

Monday through Sunday

Report Available

Same day/1 to 2 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

87899

LOINC Code Information

Test ID Test Order Name Order LOINC Value
CLFAT Cryptococcus Ag Titer, LFA, CSF 9817-8

 

Result ID Test Result Name Result LOINC Value
62076 Cryptococcus Ag Titer, LFA, CSF 9817-8

Method Name

Lateral Flow Assay (LFA)

Forms

If not ordering electronically, complete, print, and send Infectious Disease Serology Test Request (T916) with the specimen.