Test Code B190R BCR/ABL1, p190, mRNA Detection, Reverse Transcription-PCR (RT-PCR), Quantitative, Reflex, Varies
Specimen Required
Only orderable as a reflex. For more information see BCRFX / BCR/ABL1 Qualitative Diagnostic Assay with Reflex to BCR/ABL1 p190 Quantitative Assay or BCR/ABL1 p210 Quantitative Assay, Varies.
Submit only 1 of the following specimens:
Specimen Type: Whole blood
Collection Container/Tube:
Preferred: Lavender top (EDTA)
Acceptable: Yellow top (ACD)
Specimen Volume: 10 mL
Collection Instructions:
1. Invert several times to mix blood.
2. Send whole blood specimen in original tube. Do not aliquot.
3. Label specimen as blood.
Specimen Type: Bone marrow
Collection Container/Tube:
Preferred: Lavender top (EDTA)
Acceptable: Yellow top (ACD)
Specimen Volume: 4 mL
Collection Instructions:
1. Invert several times to mix bone marrow.
2. Send bone marrow specimen in original tube. Do not aliquot.
3. Label specimen as bone marrow.
Useful For
Diagnostic workup of patients with a high probability of BCR-ABL1-positive hematopoietic neoplasms, particularly acute lymphoblastic leukemia (B-lymphoblastic leukemia), to provide a pretreatment quantitative level of BCR-ABL1 mRNA transcript if the initial diagnostic reverse transcription polymerase chain reaction screen is positive
When positive, the reflex test provides a quantitative value for the corresponding e1-a2 (p190) BCR-ABL1 mRNA fusion variant.
Method Name
Only orderable as a reflex. For more information see BCRFX / BCR/ABL1 Qualitative Diagnostic Assay with Reflex to BCR/ABL1 p190 Quantitative Assay or BCR/ABL1 p210 Quantitative Assay, Varies.
Quantitative Reverse Transcription-Polymerase Chain Reaction (RT-PCR)
Reporting Name
BCR/ABL1, p190, Quant, ReflexSpecimen Type
VariesSpecimen Minimum Volume
8 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Refrigerated (preferred) | 72 hours | PURPLE OR PINK TOP/EDTA |
Ambient | 72 hours | PURPLE OR PINK TOP/EDTA |
Reject Due To
Gross hemolysis | Reject |
Moderately to severely clotted | Reject |
Clinical Information
The t(9;22)/BCR-ABL1 abnormality is associated with chronic myeloid leukemia (CML) and "Philadelphia positive" acute lymphoblastic leukemia of B-cell lineage (Ph+ ALL). Very rarely, this abnormality has also been identified in cases of acute myeloid leukemia and T-lymphoblastic leukemia/lymphoma. The fusion gene on the derivative chromosome 22q11 produces a chimeric BCR-ABL1 messenger RNA (mRNA) transcript and corresponding translated oncoprotein. Despite substantial breakpoint heterogeneity at the DNA level, a consistent set of BCR-ABL1 mRNA transcripts are produced that can be readily and sensitively detected by reverse transcription polymerase chain reaction (RT-PCR) technique. In CML, breakpoints in BCR nearly always result in either exons 13 or 14 (e13, e14) joined to exon 2 of ABL1 (a2). The corresponding e13-a2 or e14-a2 BCR-ABL1 mRNAs produce a 210 kDa protein (p210). Rare cases of CML are characterized by an e19-a2 type mRNA with a corresponding p230 protein. In Ph+ ALL, the majority of cases harbor an e1-a2 BCR-ABL1 mRNA transcript, producing a p190 protein, although some ALL patients may alternatively present with the e13/e14-a2 (p210) type fusion.
This assay provides information at the time of diagnosis regarding the presence (and specific mRNA type) or absence of the BCR-ABL1 mRNA. If positive, the reflex test will follow to provide an initial quantitative level of the specific BCR-ABL1 transcript. For example, when positive for the e1-a2 (p190) type mRNA, the reflex test provides a corresponding p190 quantitative value. Results from this test are also useful to determine the correct quantitative assay for subsequent monitoring of transcript levels (ie, p190 or p210) during tyrosine kinase inhibitor therapy.
Reference Values
Only orderable as a reflex. For more information see BCRFX / BCR/ABL1 Qualitative Diagnostic Assay with Reflex to BCR/ABL1 p190 Quantitative Assay or BCR/ABL1 p210 Quantitative Assay, Varies.
Interpretation
An interpretive report will be provided.
Cautions
In general, the results of this assay cannot be directly compared with results generated from other polymerase chain reaction (PCR) assays, including identical assays performed in other laboratories. Monitoring should be performed using the same method and laboratory for each subsequent specimen
If a rare alternative BCR-ABL1 mRNA transcript (eg, e19-a2/p230, or other) is identified by diagnostic reverse transcription polymerase chain reaction (RT-PCR), a reflex test cannot be performed as quantitative testing for these rare transcripts is not currently available.
Day(s) Performed
Monday through Friday
Report Available
7 to 10 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
81207