Test Code AER CULTURE, AEROBIC
Methodology
Conventional Culture Technique
Specimen Requirements
Submit only 1 of the following specimens:
Aspirate
Container/Tube: Sterile container(s)
- Sterile Black Top Tube or
- Sterile Red Top Tube or
- Sterile container,#6004913
Specimen Volume: 0.5 mL (minimum volume: 0.1 mL) of aspirate
Collection Instructions:
- If aspirated in a syringe, replace needle with a sterile, rubber cap prior to transporting specimen.
- Label container/syringe with patient’s legal name, date and actual time of collection, and type of specimen.
Body Fluid
Container/Tube: Sterile container(s)
- Sterile Black Top Tube or
- Sterile Red Top Tube or
- Sterile container,#6004913
Specimen Volume: 1 mL (minimum volume: 0.5 mL) of body fluid
Collection Instructions:
- If aspirated in a syringe, replace needle with a sterile, rubber cap prior to transporting specimen.
- Label container/syringe with patient’s legal name, date and actual time of collection, and type of specimen.
Swab
Container/Tube: Eswab, White, #72732
Specimen Volume: Entire specimen
Collection Instructions:
- Use a sterile culture swab to obtain specimen.
- Insert swab into moist sponge in swab container to preserve specimen.
- Label container with patient’s legal name, date and actual time of collection, and type of specimen.
Day(s) Test Set Up
Monday through Sunday
Reference Values
No growth
Performing Laboratory
Logan Health Medical Center Laboratory
Test Classification and CPT Coding
87070-Culture
87077-Aerobic identification, each (if appropriate)
87184-Kirby-Bauer, each (if appropriate)
87186-MIC, each (if appropriate)
Specimen Transport Temperature
Ambient/Refrigerate NO/Frozen NO